深圳市知用电子有限公司
ShenZhen ZhiYong Electronics Co., Ltd.
HCP8500 (500A/5 MHz)
HCP8500 (500A/5 MHz)

Bandwidth(-3dB)  DC-5MHz

Rise time   ≤70ns



浏览次数:0
说明书: 产品说明书

1.Features and Applications

The HCP8000 series current probes are wide band width DC/AC active current probes, featuring high bandwidth, fast and accurate capture the current wave, accuracy up to 1% and low circuit insertion loss. This probe can be used with any oscilloscope having a high-impedance BNC input.


Model

HCP8500

Bandwidth

(-3dB)

DC-5MHz

(Figure13)

Rise time

≤70ns

Continuous

maximum input

range

500Arms

(Figure14)

Max peak current value

750Apk

Range

75A

10X

500A

100X

Overload

75A

≥75A

500A

≥750A

Current transfer ratio

75A

0.1V/A

500A

0.01V/A

measurable

current

75A

10mA

500A

100mA

Amplitude

accuracy (DC,45-66Hz )

75A

±1%±10mA

500A

±1%±100mA

Input

impedance

Reference(Figure15)

Delay

time

Probe

42ns

BNC

(1m)

5ns

Terminal load

≥100kΩ

Power supply

DC 12V/1AStandard Adaptor

Voltage of insulated wire

600V CATII  300V CATIII

Safety compliance

EN61010-1: 2010+A1:2019  EN 61010-2-032:2019

EMC standard

EN61326-1:2013  EN61000-3-2:2014  EN61000-3-3:2013