Frequency resolution 1Hz
Attenuation 0dB—30dB
Measurement Accuracy (Typical) ±1.5dB
1. Summary
EM5080A (9kHz-30MHz) receiver is a kind of Pre-compliance EMI Receiver that based on the SDR platform. EM5080A is digitalized receiver which can be operating by standard PC software and make the test process easy for the users. All of these make EM5080A very cost-effective.
EM5080A is compliance with CISPR 16-1. It is very useful in the standard EMI measurement such as CISPR, EN550XX, FCC and MIL. It is especially good for the EMI test for household electrical appliances (CISPR 14-1) and lighting equipment.
EM5080A Receiver can be switched to FFT spectrum analyzer mode with RBW 1.5kHz and its fast scanning speed make it a powerful equipment for different kind of debugging test.
specification
Frequency Range | 9kHz-30MHz | ||
Frequency resolution | 1Hz | ||
Measurement Accuracy | <1ppm | ||
RF input | 50Ω,SMA fem. | ||
VSWR | 30dB RF att. | <1.2 | |
0dB RF att. | <2 | ||
Attenuation | 0dB—30dB | ||
Measurement Accuracy (Typical) | ±1.5dB | ||
Max Input Level(If equipment is not damaged) | |||
Sinusoidal Voltage | 120dBuV | ||
Density of Impulse Frequency | +97dBμV/MHz | ||
Preselector | |||
Fixed bandpass filter |
LP-150kHz 150kHz-4.05MHz 4.05MHz-12.8MHz 12.8MHz-21.55MHz 21.55MHz-30MHz | ||
IF Bandwidth | |||
6dB | 0.2 and 9kHz (CISPR 16-1-1) |
Displayed average noise level (DANL) | |
9kHz-150kHz (200Hz BW) | <0dBμV(QP) typical |
<-5dBμV(AV) typical | |
150kHz-30MHz (9kHz BW) | <5dBμV(QP) typical |
<0dBμV(AV) typical | |
Detector |
Peak, quasi-peak, CISPR average |
Test Time(Dwell Time) |
PK/AV:5-500ms Adjustable QP:1s-15s Adjustable |
Image Rejection | 90dB typical |
Display Unit | dB μV dBm |
Real time FFT spectrum analyzer mode | 1.5kHz RBW |
Communication port | USB2.0 |
Power Supply | DC12V/1A |
Operating Temperature | 0℃~45℃ |
Size | 193*134*58mm |
Weight | 1kg |