1. Summary
HVP6000E series is the high voltage high frequency differential probe with floating ground measurement function. It can reach up to differential voltage of 7000Vpk and bandwidth of 100MHz, and the typical accuracy of 1% can fulfill the need for most measurement system. HVP6000E has standard BNC output connector, allowing it to operate with oscilloscope of any brand.
HVP6000E series has USB communication function, and it can interact with the Smart Probe Adaptor of our company, adjusting the parameter including model, voltage type, attenuation ratio and delay corresponding to the smart probe connected. This device solved the trouble of manually setting up parameter when using a third party probe on oscilloscope and provide the same experience as those probes of certain brands.
Electronics Specifications
Model | HVP6150E | HVP6350E | HVP6700E | ||||
Bandwidth(-3dB) | 100MHz | ||||||
Rise time | ≤3.5ns | ||||||
Accuracy (% of the reading) | ±1% | ||||||
Range option (attenuation ratio) | 50X/500X | 100X/1000X | 100X/1000X | ||||
Maximum differential measurement voltage (DC + Peak AC) | 50X | ±150V | 100X | ±350V | 100X | ±700V | |
500X | ±1500V | 1000X | ±3500V | 1000X | ±7000V | ||
Common mode voltage (DC + Peak AC) | ±1500V | ±3500V | ±7000V | ||||
Maximum differential mode voltage vs frequency curve | Refer to Fig. 1 | Refer to Fig. 2 | Refer to Fig. 3 | ||||
Maximum input-to-ground voltage (Vrms) | 600V CATIII 1000V CATII | 600V CATIII 1000V CATII | 1000V CATIII 1500V CATII | ||||
Input impedance | Single end to ground | 5MΩ | 20MΩ | 20MΩ | |||
Two input terminals | 10MΩ | 40MΩ | 40MΩ | ||||
Input capacity | Single end to ground | <4pF | <4pF | <5pF | |||
Two input terminals | <2pF | <2pF | <2.5pF | ||||
CMRR | DC | >80dB | >80dB | >80dB | |||
100kHz | >60dB | >60dB | >60dB | ||||
1MHz | >50dB | >50dB | >50dB | ||||
Noise (Vrms) | 50X | <60mV | 100X | <155mV | 100X | <250mV | |
500X | <300mV | 1000X | <600mV | 1000X | <1V | ||
Threshold value of voltage overload indication | 50X | ≥150V | 100X | ≥350V | 100X | ≥700V | |
500X | ≥1500V | 1000X | ≥3500V | 1000X | ≥7000V | ||
Delay time | Probe | 50X | 15.5ns | 100X | 15.5ns | 100X | 15.5ns |
500X | 14.5ns | 1000X | 14.5ns | 1000X | 14.5ns | ||
Bandwidth limit(5MHz) | ≥-3dB@5MHz | ||||||
Overvoltage indicator light (red light) | YES | ||||||
Overvoltage alarm sound | YES | ||||||
Auto-save function | YES | ||||||
Auto-zero function | YES | ||||||
Bias voltage elimination function | YES | ||||||
Terminal load requirements | ≥100kΩ | ||||||
power supply | USB 5V/2.4A Adaptor | ||||||
Safety standards | IEC 61010-031: 2022, EN IEC 61010-031: 2023 | ||||||
EMC standard | EN IEC 61326-1:2021 EN IEC 61000-3-2:2019+A1:2021+A2:2024 EN 61000-3-3:2013+A1:2019+A2:2021 |