1.Features and Applications
The HCP8000 series current probes are wide band width DC/AC active current probes, featuring high bandwidth, fast and accurate capture the current wave, accuracy up to 1% and low circuit insertion loss. This probe can be used with any oscilloscope having a high-impedance BNC input.
Large Pliers
Model  | HCP8150(A)  | HCP8300(A)  | HCP8500  | ||||
Bandwidth (-3dB)  | HCP8150  | DC-12 MHz (Figure 10.a)  | HCP8300  | DC- 6 MHz (Figure 13.a)  | DC-5MHz (Figure 16)  | ||
HCP8150A  | DC-22 MHz (Figure 10.b)  | HCP8300A  | DC-8 MHz (Figure 13.b)  | ||||
Rise time  | HCP8150  | ≤29ns  | HCP8300  | ≤58ns  | ≤70ns  | ||
HCP8150A  | ≤16ns  | HCP8300A  | ≤50ns  | ||||
Continuous maximum input range  | HCP8150  | 150Arms (Figure 11.a)  | HCP8300  | 300Arms (Figure 14.a)  | 500Arms(Figure 17)  | ||
HCP8150A  | 150Arms (Figure 11.b)  | HCP8300A  | 300Arms (Figure 14.b)  | ||||
Max peak current value  | 300Apk  | 500Apk  | 750Apk  | ||||
Range  | 30A  | 10X  | 50A  | 10X  | 75A  | 10X  | |
150A  | 100X  | 300A  | 100X  | 500A  | 100X  | ||
Overload  | 30A  | ≥30APk  | 50A  | ≥50APk  | 75A  | ≥75APk  | |
150A  | ≥300APk  | 300A  | ≥500APk  | 500A  | ≥750APk  | ||
Current transfer ratio  | 30A  | 0.1V/A  | 50A  | 0.1V/A  | 75A  | 0.1V/A  | |
150A  | 0.01V/A  | 300A  | 0.01V/A  | 500A  | 0.01V/A  | ||
measurable current  | 30A  | 10mA  | 50A  | 10mA  | 75A  | 10mA  | |
150A  | 100mA  | 300A  | 100mA  | 500A  | 100mA  | ||
Amplitude accuracy (DC,45-66Hz )  | 30A  | ±1%±10mA  | 50A  | ±1%±10mA  | 75A  | ±1%±10mA  | |
150A  | ±1%±100mA  | 300A  | ±1%±100mA  | 500A  | ±1%±100mA  | ||
Input impedance  | HCP8150  | Referenc (Figure 12.a)  | HCP8300  | Reference(Figure 15.a)  | Reference (Figure 18)  | ||
HCP8150A  | Referenc (Figure 12.b)  | HCP8300A  | Reference(Figure 15.b)  | ||||
Delay time  | Probe  | HCP8150  | 36ns  | 41ns  | 42ns  | ||
HCP8150A  | 30ns  | ||||||
BNC (1m)  | 5ns  | ||||||
Terminal load  | ≥100kΩ  | ||||||
Power supply  | DC 12V/1A(Standard Adaptor)  | ||||||
Voltage of insulated wire  | 600V CATII 300V CATIII  | ||||||
Safety compliance  | EN61010-1: 2010+A1:2019 EN 61010-2-032:2019  | ||||||
EMC standard  | EN61326-1:2013 EN61000-3-2:2014 EN61000-3-3:2013  | ||||||